top of page

ACI for Mercury Removal

Integrated with Proprietary Kinetic Chemistry Submodels

 

RAS has significant modeling experience and strong capability in design and optimization of Dry Sorbent Injection (DSI) and Activated Carbon Injection (ACI) technology for pollutants removal from flue gas. In addition to Conventional CFD flow modeling, we have incorporated a number of our in-house proprietary sorbent chemistry sub-models, including:

  • Hydrated lime + SO3

  • Hydrated lime + HCl/SO2

  • Trona/SBC + HCl/SO2

  • Trona/SBC + SO3

  • Activated carbon + Hg/HgCl2

CFD ACI chemistry model to predict carbon mixing and remove mercury
CFD ACI chemistry model to predict carbon mixing and remove mercury

CFD predictions of mercury reduction by ACI injection at a 750 MWe coal-fired boiler. (upper) particle trajectory and carbon concentration; (lower) elemental and oxidized mercury concentration predicted by chemistry model.

© 2023 by Reaction Analytic Solutions Corp. All rights reserved.